| 000 | 02554nam a22001337a 4500 | ||
|---|---|---|---|
| 999 |
_c16223 _d16223 |
||
| 245 | _aIEC 60942:2017-Electroacoustics - Sound calibrators | ||
| 250 | _a4.0 | ||
| 260 |
_aGeneva : _bInternational Electrotechnical Commission, _c2017. |
||
| 300 | _a112 p. | ||
| 505 | _aIEC 60942:2017 is also available as IEC 60942:2017 RLV which contains the International Standard and its Redline version, showing all changes of the technical content compared to the previous edition. IEC 60942:2017 specifies the performance requirements for three classes of sound calibrator: class LS (Laboratory Standard), class 1 and class 2. Acceptance limits are smallest for class LS and greatest for class 2 instruments. Class LS sound calibrators are normally used only in the laboratory; class 1 and class 2 are considered as sound calibrators for field use. A class 1 sound calibrator is primarily intended for use with a class 1 sound level meter and a class 2 sound calibrator primarily with a class 2 sound level meter, as specified in IEC 61672-1. The acceptance limits for class LS sound calibrators are based on the use of a laboratory standard microphone, as specified in IEC 61094-1, for demonstrations of conformance to the requirements of this document. The acceptance limits for class 1 and class 2 sound calibrators are based on the use of a working standard microphone, as specified in IEC 61094-4, for demonstrations of conformance to the requirements of this document. This fourth edition cancels and replaces the third edition published in 2003, of which it constitutes a technical revision. This edition includes the following significant technical changes with respect to the previous edition: a) deletion of the class designations, class LS/C, class 1/C and class 2/C; b) addition of two further class designations, class LS/M and class 1/M, specifically for pistonphones; c) addition of an amended criterion for assessing conformance to a specification: conformance is now demonstrated when (a) measured deviations from design goals do not exceed the applicable acceptance limits and (b) the uncertainty of measurement does not exceed the corresponding maximum-permitted uncertainty; d) modification to the short-term level fluctuation test of the sound pressure level stability; e) change to some environmental test conditions to avoid icing; f) addition of an alternative test for immunity to radio-frequency fields using transverse electromagnetic (TEM) waveguides. | ||
| 650 | _aElectroacoustics | ||
| 650 | _aSound calibrators | ||
| 942 | _cST | ||