<?xml version="1.0" encoding="UTF-8"?>
<mods xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xmlns="http://www.loc.gov/mods/v3" version="3.1" xsi:schemaLocation="http://www.loc.gov/mods/v3 http://www.loc.gov/standards/mods/v3/mods-3-1.xsd">
  <titleInfo>
    <title>Short-Term Reliability of Different Methods of Contralateral Suppression of Transient Evoked Otoacoustic Emission in Children and Adults</title>
  </titleInfo>
  <name type="personal">
    <namePart>Shreyank P. Swamy</namePart>
    <role>
      <roleTerm authority="marcrelator" type="text">creator</roleTerm>
    </role>
  </name>
  <name type="personal">
    <namePart>Asha Yathiraj</namePart>
  </name>
  <typeOfResource>text</typeOfResource>
  <originInfo>
    <place>
      <placeTerm type="code" authority="marccountry">xx</placeTerm>
    </place>
    <publisher>ASHA</publisher>
    <dateIssued>2019</dateIssued>
    <dateIssued encoding="marc">9999</dateIssued>
    <issuance>monographic</issuance>
  </originInfo>
  <language>
    <languageTerm authority="iso639-2b" type="code">und</languageTerm>
  </language>
  <physicalDescription>
    <form authority="marcform">print</form>
    <extent>495-507</extent>
  </physicalDescription>
  <abstract>Purpose :This study aimed to investigate the reliability of 3 methods to measure contralateral suppression of transient evoked otoacoustic emissions (TEOAEs) in children and adults.Method:Contralateral suppression of TEOAEs was measured in 14 adults and 14 children using 3 methods with and without contralateral acoustic stimulus (CAS). Method-I having “2 s on-off” and Method-II having “10 s on-off” interleaved presentation of white noise. Method-III used “continuous presentation of white noise”. Test–retest reliability was checked in adults without removing the probe (same-probe recording) and reinserting the probe (different-probe recording) and in children using a different-probe recording.Results:The absolute suppression amplitude of TEOAEs was higher for “continuous noise,” followed by “10 s on-off” and “2 s on-off” CAS. There was no significant effect of age across the 2 probe recordings, 3 methods of TEOAEs with and without CAS, and for the absolute suppression amplitude. Also, in adults, there was no significant difference between same-probe and different-probe recordings across the 3 methods. High internal consistency was observed on Cronbach's alpha (α &gt; .9) for the 3 methods and 2 probe recordings. High agreement and correlation between the recordings for all 3 methods were seen using Bland–Altman plots and Pearson product–moment correlation coefficient.Conclusion:The study demonstrated that highly reliable contralateral suppression of TEOAE can be measured using the 3 methods in adults and children. However, continuous presentation of CAS resulted in greater TEOAE suppression amplitude compared to interleaved presentation of CAS; hence, the former is recommended.</abstract>
  <relatedItem type="host">
    <name>
      <namePart>American Journal of Audiology</namePart>
    </name>
  </relatedItem>
  <identifier type="issn">1558-9137</identifier>
  <identifier type="uri">https://doi.org/10.1044/2018_AJA-IND50-18-0093</identifier>
  <location>
    <url>https://doi.org/10.1044/2018_AJA-IND50-18-0093</url>
  </location>
  <recordInfo>
    <recordCreationDate encoding="marc">210629</recordCreationDate>
  </recordInfo>
</mods>
