ISO 11904-1:2002-Acoustics — Determination of sound immission from sound sources placed close to the ear - Part 1: Technique using a microphone in a real ear (MIRE technique)

Material type: TextPublication details: Geneva : International Organization for Standardization 2002.Description: 28 pSubject(s):
Contents:
ISO 11904-1:2002 specifies basic framework measurement methods for sound immissions from sound sources placed close to the ear. These measurements are carried out with miniature or probe microphones inserted in the ear canals of human subjects. The measured values are subsequently converted into corresponding free-field or diffuse-field levels. The results can be given as free-field related or diffuse-field related equivalent continuous A-weighted sound pressure levels. The technique is denoted the microphone-in-real-ear technique (MIRE technique). ISO 11904-1:2002 is applicable to exposure from sources close to the ear, for example during equipment tests or at the workplace by earphones or hearing protectors with audio communication facilities. ISO 11904-1:2002 is applicable in the frequency range from 20 Hz to 16 000 Hz.
Tags from this library: No tags from this library for this title. Log in to add tags.
Star ratings
    Average rating: 0.0 (0 votes)
Holdings
Cover image Item type Current library Home library Collection Shelving location Call number Materials specified Vol info URL Copy number Status Notes Date due Barcode Item holds Item hold queue priority Course reserves
Standards All India Institute of Speech and Hearing Available ST046
Total holds: 0

ISO 11904-1:2002 specifies basic framework measurement methods for sound immissions from sound sources placed close to the ear. These measurements are carried out with miniature or probe microphones inserted in the ear canals of human subjects. The measured values are subsequently converted into corresponding free-field or diffuse-field levels. The results can be given as free-field related or diffuse-field related equivalent continuous A-weighted sound pressure levels. The technique is denoted the microphone-in-real-ear technique (MIRE technique).

ISO 11904-1:2002 is applicable to exposure from sources close to the ear, for example during equipment tests or at the workplace by earphones or hearing protectors with audio communication facilities.

ISO 11904-1:2002 is applicable in the frequency range from 20 Hz to 16 000 Hz.