Comparison of hearing thresholds using audiometric versus android-based application (Record no. 17816)
[ view plain ]
| 000 -LEADER | |
|---|---|
| fixed length control field | 02797caa a2200265 4500 |
| 022 ## - INTERNATIONAL STANDARD SERIAL NUMBER | |
| International Standard Serial Number | 2249-9520 |
| 100 ## - MAIN ENTRY--PERSONAL NAME | |
| Personal name | Prithivi, T |
| 245 #0 - TITLE STATEMENT | |
| Title | Comparison of hearing thresholds using audiometric versus android-based application |
| 260 ## - PUBLICATION, DISTRIBUTION, ETC. | |
| Date of publication, distribution, etc. | 2019 |
| 270 ## - ADDRESS | |
| Address | Department of Audiology, All India Institute of Speech and Hearing, Mysore - 570 006, Karnataka |
| 300 ## - PHYSICAL DESCRIPTION | |
| Extent | 206-209 |
| 490 ## - SERIES STATEMENT | |
| Volume/sequential designation | Volume 25 Issue 4 |
| 520 ## - SUMMARY, ETC. | |
| Summary, etc. | Background: Hearing loss is a highly widespread problem worldwide and early identification of hearing loss through screening is important to overcome the negative effects of untreated hearing impairment. Screening can be done using handheld device app technologies for the hearing assessments that would be easy to be used by any individual. Aims and Objectives: The aim of the present study was to compare the hearing thresholds with smartphone application and conventional audiometer. Materials and Methods: A total of 52 participants were included in the study. They were divided into two groups. Group 1 included 36 participants (72 ears) in the age range of 7 to 35 years with normal hearing sensitivity. Group 2 included 16 participants (32 ears) in the age range of 18-68 years with varying degree of hearing loss ranging from minimal hearing loss to severe hearing loss. Thus, a total of 104 ears were tested. Air Conduction thresholds were obtained at octave frequencies from 250 Hz to 4000 Hz using conventional audiometer in a sound treated room and through the android application (Hearing test version 1.1.) using a smart phone (Micromax Xpress Canvas) in a quiet room. The noise levels for hearing assessment through smart phone app ranged between 70-75 dB A, which was measured prior to the testing session. The thresholds were obtained for both right and left ear of the participants. The hearing thresholds obtained from both the measures was subjected to appropriate statistical analysis. Results: The results showed that there was a significant difference in the thresholds across the procedures for all the frequencies in Group 1. However, there was no significant difference in thresholds across the procedures for all the frequencies in Group 2. Conclusion: It can be concluded that hearing screening through mobile application is user-friendly and cost-effective, but it might lead into under referrals. |
| 653 ## - INDEX TERM--UNCONTROLLED | |
| Uncontrolled term | Audiometry, hearing screening, mobile applications |
| 700 ## - ADDED ENTRY--PERSONAL NAME | |
| Personal name | Banoth Shoban |
| 700 ## - ADDED ENTRY--PERSONAL NAME | |
| Personal name | Chandan Kumar Nayak |
| 700 ## - ADDED ENTRY--PERSONAL NAME | |
| Personal name | Chandni Jain |
| 700 ## - ADDED ENTRY--PERSONAL NAME | |
| Personal name | Jeevan, G |
| 700 ## - ADDED ENTRY--PERSONAL NAME | |
| Personal name | Kavitha, G. S |
| 700 ## - ADDED ENTRY--PERSONAL NAME | |
| Personal name | Pruthvik, S. P |
| 773 ## - HOST ITEM ENTRY | |
| Main entry heading | Indian Journal of Otology |
| 856 ## - ELECTRONIC LOCATION AND ACCESS | |
| Uniform Resource Identifier | https://www.indianjotol.org/text.asp?2019/25/4/206/272229 |
| 942 ## - ADDED ENTRY ELEMENTS (KOHA) | |
| Koha item type | Faculty Publications |
| -- | FJAS |
No items available.