Snow
All India Institute of Speech and Hearing, Mysuru
(An Autonomous institute Under Ministry of Health and Family Welfare, Government of India.)

Library and Information Center

Effects of nonlinear amplification on differential sensitivity measures in individuals with cochlear hearing impairment (Record no. 17810)

MARC details
000 -LEADER
fixed length control field 02495caa a2200229 4500
022 ## - INTERNATIONAL STANDARD SERIAL NUMBER
International Standard Serial Number 2249-9520
100 ## - MAIN ENTRY--PERSONAL NAME
Personal name Devi, N
245 #0 - TITLE STATEMENT
Title Effects of nonlinear amplification on differential sensitivity measures in individuals with cochlear hearing impairment
260 ## - PUBLICATION, DISTRIBUTION, ETC.
Date of publication, distribution, etc. 2017
270 ## - ADDRESS
Address Department of Audiology, All Institute of Speech and Hearing, Mysore, Karnataka, India
270 ## - ADDRESS
Address Department of Audiology, Rehabilitative Health Sciences, College of Applied Medical Sciences, KSU, Riyadh, Saudi Arabia
300 ## - PHYSICAL DESCRIPTION
Extent 162-167
490 ## - SERIES STATEMENT
Volume/sequential designation Volume 23 Issue 3
520 ## - SUMMARY, ETC.
Summary, etc. Objective: The current study focused on exploring the influence of multichannel amplification with wide dynamic range compression (WDRC) on frequency, intensity, and duration discrimination measures at two frequencies in different channels of amplification. Methods: Discrimination measures were performed on twenty ears with moderate flat sensorineural hearing loss using 2-down and 1-up adaptive procedure to achieve 70.7% response on the psychometric function. All stimuli were generated through AUX script and presented using Psycon version 2.18 experimental software and delivered through the speakers oriented at an angle of 0° azimuth. Discrimination measures were performed in both aided and unaided conditions for two pure tone frequencies of 750 and 1500 Hz with 500 ms duration (on/off ramp duration of 80 ms to avoid spectral splatter) presented at a level of 20 dBSL (with reference to the threshold separately in each condition). The responses were recorded through three interval alternative forced choice paradigm with visual feedback. An average of final four reversals out of eight was considered for discrimination threshold estimation. Results and Conclusions: Results revealed a statistically significant deterioration in intensity discrimination and a significant improvement in difference limen for frequency and duration with nonlinear amplification. The deteriorated intensity discrimination scores were explained in perspectives of WDRC acting in amplification device.
653 ## - INDEX TERM--UNCONTROLLED
Uncontrolled term Duration discrimination, frequency discrimination, intensity discrimination, just noticeable difference in cochlear hearing loss and amplification affects
700 ## - ADDED ENTRY--PERSONAL NAME
Personal name Amritha, G
700 ## - ADDED ENTRY--PERSONAL NAME
Personal name Kishore Tanniru
773 ## - HOST ITEM ENTRY
Main entry heading Indian Journal of Otology
856 ## - ELECTRONIC LOCATION AND ACCESS
Uniform Resource Identifier https://doi.org/10.4103/indianjotol.INDIANJOTOL_2_17
942 ## - ADDED ENTRY ELEMENTS (KOHA)
Koha item type Faculty Publications
-- FJAS