Snow
All India Institute of Speech and Hearing, Mysuru
(An Autonomous institute Under Ministry of Health and Family Welfare, Government of India.)

Library and Information Center

Effect of Varied Gradation Levels of Noise Reduction Algorithm on Speech Perception through Acoustical and Perceptual Measures (Record no. 17781)

MARC details
000 -LEADER
fixed length control field 02474caa a2200229 4500
022 ## - INTERNATIONAL STANDARD SERIAL NUMBER
International Standard Serial Number 2474-7556
100 ## - MAIN ENTRY--PERSONAL NAME
Personal name Sharath Kumar, K.S
245 #0 - TITLE STATEMENT
Title Effect of Varied Gradation Levels of Noise Reduction Algorithm on Speech Perception through Acoustical and Perceptual Measures
260 ## - PUBLICATION, DISTRIBUTION, ETC.
Date of publication, distribution, etc. 2017
270 ## - ADDRESS
Address Department of Audiology (New JC block), Manasagangotri, AIISH, Mysuru - 570 006, Karnataka, India, Tel: +919845421986
270 ## - ADDRESS
Address Professor of Audiology, Department of Audiology, Manasagangotri, AIISH, Mysuru - 570 006 India, Karnataka
270 ## - ADDRESS
Electronic mail address manjulap21@hotmail.com
270 ## - ADDRESS
Electronic mail address sharathkumarks08@gmail.com
490 ## - SERIES STATEMENT
Volume/sequential designation Volume 5 Issue 2
520 ## - SUMMARY, ETC.
Summary, etc. Purpose: The purpose of the study was to evaluate the effect of different gradations of noise reduction (NR) algorithm in hearing aids, through acoustical and perceptual measures.Methods: The output of the hearing aid with NR at three gradations (minimum, medium and maximum) and without NR, at 0 dB signal to noise ratio (SNR) across three types of noise (cafeteria, speech babble, and traffic noise) was recorded. The effect of noise reduction was quantified through objective and subjective measures.Results: In noise alone condition, the maximum gain reduction was seen for the traffic noise followed by cafeteria noise and speech babble. In the speech in noise condition, the maximum improvement in the output SNR was seen only for cafeteria noise and traffic noise. However, the NR gradation did not have much impact on speech babble. The Perceptual Evaluation of Speech Quality results revealed that the mean opinion scores were similar across the NR 'on' and NR 'off' positions. However, Envelope Detection Index values for maximum NR gradation was better than medium and minimum gradation for cafeteria noise and traffic noise. Hence, it was seen that the effectiveness of NR depended on the type of noise. The subjective quality judgment tasks were also in coherence with the objective measures.Conclusion: When NR was set to maximum, it could aid in reducing the noisiness and improving the overall quality of the signal for cafeteria and traffic noise.
653 ## - INDEX TERM--UNCONTROLLED
Uncontrolled term Acoustic analysis; EDI; Hearing aid; Noise reduction algorithm - gradation; PESQ; Quality judgment; WADA-SNR
700 ## - ADDED ENTRY--PERSONAL NAME
Personal name Manjula, P
773 ## - HOST ITEM ENTRY
Main entry heading Global Journal of Otolaryngology
856 ## - ELECTRONIC LOCATION AND ACCESS
Uniform Resource Identifier https://doi.org/10.19080/GJO.2017.05.555659
942 ## - ADDED ENTRY ELEMENTS (KOHA)
Koha item type Faculty Publications
-- FJAS

No items available.