Effect of personal music system use on sacculocollic reflex assessed by cervical vestibular-evoked myogenic potential: A preliminary investigation (Record no. 17709)
[ view plain ]
| 000 -LEADER | |
|---|---|
| fixed length control field | 02260caa a2200205 4500 |
| 022 ## - INTERNATIONAL STANDARD SERIAL NUMBER | |
| International Standard Serial Number | 1998-4030 |
| 100 ## - MAIN ENTRY--PERSONAL NAME | |
| Personal name | Niraj Kumar Singh |
| 245 #0 - TITLE STATEMENT | |
| Title | Effect of personal music system use on sacculocollic reflex assessed by cervical vestibular-evoked myogenic potential: A preliminary investigation |
| 260 ## - PUBLICATION, DISTRIBUTION, ETC. | |
| Date of publication, distribution, etc. | 2016 |
| 270 ## - ADDRESS | |
| Address | Department of Audiology, All India Institute of Speech and Hearing, Mysore, Karnataka, India |
| 300 ## - PHYSICAL DESCRIPTION | |
| Extent | 104-112 |
| 490 ## - SERIES STATEMENT | |
| Volume/sequential designation | Volume 18 Issue 81 |
| 520 ## - SUMMARY, ETC. | |
| Summary, etc. | Listening to music through a portable personal music system (PMS) is a growing trend, especially among the youth. The preferred listening level in such kinds of PMS has been reported to cross the safe levels and its impact on the auditory system was demonstrated in several previous investigations. Owing to the commonality in several aspects between the auditory and the vestibular systems, it appears likely that the deleterious effects of PMS use could also be impinging on the vestibular system, which has never been investigated. The present study therefore, aimed at evaluating the effects of PMS use on the sacculocollic reflex assessed by the cervical vestibular-evoked myogenic potential (cVEMP) technique. Thirty-two regular PMS users and 32 nonregular PMS users underwent cVEMP testing using alternating polarity 500 Hz tone bursts. The results revealed no significant group difference in latencies and interaural asymmetry ratio. However, the cVEMP was significantly reduced in the group of individuals in whom the diffused field equivalent sound pressure levels (SPLs) were above the damage risk criteria (DRC) compared to those with diffused field equivalent SPLs below it (P< 0.01). Therefore, the use of PMS at high levels of volume controls could be deleterious to the vestibular well-being of an individual. |
| 653 ## - INDEX TERM--UNCONTROLLED | |
| Uncontrolled term | Cervical vestibular-evoked myogenic potential (cVEMP), noise-induced hearing loss (NIHL), personal music system (PMS), sacculocollic reflex |
| 700 ## - ADDED ENTRY--PERSONAL NAME | |
| Personal name | Chithra Sobha Sasidharan |
| 773 ## - HOST ITEM ENTRY | |
| Main entry heading | Noise Health |
| 856 ## - ELECTRONIC LOCATION AND ACCESS | |
| Uniform Resource Identifier | https://www.noiseandhealth.org/article.asp?issn=1463-1741;year=2016;volume=18;issue=81;spage=104;epage=112;aulast=Singh;type=2 |